0–10V
Analog speed control
HVAC ECM DRIVER BOARDS
External Sensorless Motor Control for HVAC Fans & Blowers

M1 is a sensorless external ECM motor control board designed for HVAC fan, blower and fan coil applications. As a compact ECM / BLDC motor driver, it supports stepless 0–10V speed control, 3-speed control and RS485 communication, providing flexible speed control for different HVAC operating requirements.
Unlike a universal motor controller, M1 can be programmed and matched to specific ECM / BLDC motors according to motor characteristics, target RPM, airflow and application requirements. A built-in 6-position DIP switch provides motor rotation setting and multiple preset speed configurations, making the board suitable for customized HVAC OEM/ODM projects. M1 can be supplied as part of a matched ECM motor + external driver solution for fan coil units (FCU), HVAC fans, blowers and other air-moving equipment.
| Item | Specification |
|---|---|
| Model | M1 |
| Motor control | Sensorless ECM / BLDC |
| Max motor power | ≤80W |
| Input voltage | 170–240VAC |
| Control interface | 0–10V / 3-Speed / RS485 |
| Speed levels | Up to 31 configurable levels |
| Firmware | Motor-matched custom firmware |
| Dimensions | 110 × 92 mm |
| Certification | CE / RoHS / UL / ETL / CSA compliance |


Analog speed control
Multi-speed control
Modbus communication
Motor-matched parameters
No Hall sensors required
Send us your motor information
to get initial recommendations.
Flexible control interfaces for different HVAC motor and system requirements. Availability depends on the selected driver and application.
Yes. Compatibility is evaluated according to the motor voltage, power, electrical characteristics, target speed and HVAC application requirements.
No. M1 uses sensorless ECM / BLDC motor control and does not require Hall sensor feedback from the motor.
M1 is designed for compatible HVAC ECM / BLDC motor applications up to 80W, subject to motor matching and application verification.
M1 supports 0–10V, 3-speed and RS485 control. Availability and settings can be configured for the project.
Yes. Motor parameters, startup behavior, speed range and control logic can be matched to the motor and HVAC application.
Yes. Send us your motor information and application requirements so our engineering team can evaluate compatibility and prepare a matched sample.
LET’S BUILD A SMARTER HVAC SOLUTION TOGETHER
Send us your application requirements, motor specifications, drawings or control requirements.